500 Series Straight Flow Valves with Reclaimed Purple Cap

A straight flow valve has a patented open flow design. There are no 90 degree angles that the flow of water has to maneuver around. This allows for flow rates as far low as 1 GPH. The diaphragm inside does not cause hammering when closing like a typical valve.

510-050-R

1” Nylon Female Thread Inlet and Outlet
Flow Control
Reclaimed Purple Cap
Overall Height: 6”
Overall Width: 3 – 1/2”
Overall Length 5”

515-050-R

1 – 1/2” Nylon Female Thread Inlet and Outlet
Flow Control
Reclaimed Purple Cap
Overall Height: 6”
Overall Width: 4 – 1/2”
Overall Length 7”

Features

• Patented full open straight through flow design
• Extremely low pressure loss
• Low flow capability from 1 GPH
• Contamination resistant w/ internal control water filtration
• Internal manual bleed operation
• Manual bleed can be removed for “tamper proof” operation
• Heavy duty reinforced EPDM diaphragm
• 33% glass filled nylon construction
• Heavy duty brass threaded retainer nuts in body (6 bolt pattern)
• Heavy duty stainless steel bolts for bonnet assembly (6 bolt pattern)
• Heavy duty stainless steel flow control stem
• 1” available with flow or non flow control, threaded or socket (glass filled PVC body)
• Ideal for commercial applications

Full Open Straight Flow

Electrical Specifications

  • 24 VAC standard
  • Inrush: 350 mA
  • Holding: 250 mA
  • Cycles: 50 Hz to 60 Hz

Operating Specifications

• 1” Flow: 1 GPH – 50 GPM
• 1 1/2” Flow: 1 – 110 GPM
• 2” Flow: 2 – 250 GPM
• 3” Flow: 5 GPM – 250 GPM
• Operating pressure: 15 to 200 PSI
• Recommended velocity not to exceed 5 feet per second of corresponding pipe size
• Downstream pressure adjustable from 15-150 PSI
• All valves for outdoor use only

Specific Reclaimed Cap Features

• Reclaimed purple flow control handle and bonnets
• Ideal for reclaimed and non-potable water residential and commercial applications

Pressure Loss with 1″ Valve

Flow (GPM) Pressure Loss (PSI)
15 1.20
20 2.10
25 4.00
30 5.00
35 6.20
40 8.0
45 10

Pressure Loss with 1-1/2″ Valve

Flow (GPM) Pressure Loss (PSI)
40 2.00
45 2.20
60 2.60
80 3.00
100 4.00
150 8.00

Pressure Loss with 2″ Valve

Flow (GPM) Pressure Loss (PSI)
40 1.50
45 1.80
60 3.00
80 3.00
100 4.00
150 5.00
200 7.00

Pressure Loss with 3″ Valve

Flow (GPM) Pressure Loss (PSI)
45 1.80
60 3.00
80 3.00
100 4.00
150 5.00
200 7.00
250 10.00